[1] A.E. Schach von wittenau, P.M. Bergstrom, L.J. Cox. Patient-dependent beam –modifier Physics in Monte Carlo photon dose calculations, Med Phys, 27(5) (2000) 935–47.
[2] A. Chaves, M.C. Lopes, C.C. Alves, C. Oliveria, L. Peralta, P. Rodrigues, A. Trindade. Basic dosimetry of radiosurgery narrow beams dosimetry of radiosurgery narrow beams using Monte Carlo simulation: A detailed study Of depth of maximum dose, Med Phys, 30(11) (2003) 2904–2911.
[3] I. Chetty, J.J. Demarco, T.D. Solberg. A virtual source model for Monte Carlo modeling of arbitraray intensity distribution, Med Phys, 27 (2000) 166–172.
[4] A. Chaves, M.C. Lopes, C.C. Alves. A Monte Carlo multiple source model applied toradiosurgery narrow photon beam, Med Phys. 31(8) (2004) 2196–2204.
[5] F. Verhaegen, J. Seuntjens. Monte Carlo modeling of external radiotherapy photon beams. Phys Med Biol. 48 (2003) R107–64.
[6] X.G. Ding, Using Monte Carlo simulation to commission photon beam output factors-a feasibility study, Phys Med Biol. 48 (2003) 3865–3874.
[7] D. Sheikh-Bagheri, D.W. Rogers. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Med Phys 29(3) (2002) 391–402.
[8] M.K. Fix, H. Keller, P. Rugesegger, E.J Born. Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy, Med Phys. 27(12) (2000) 2739–2747.
[9] S.Y. Lin, T.C. J.P. Chu, Lin. Monte Carlo simulation of a clinical linear accelerator, Applied Radiation and Isotopes. 55 (2001) 759–765.
[10] H. Helen, T. Rock Mackie, C. Edwin. A dual source photon beam model used in convolution/superposition dose calculation for clinical megavoltage x-ray beams, Med. Phys. 24(12) (1997) 1960–74 .
[11] R.D. Lewist, S.J. Ryde, D.A. Hancock, C.J. Evans. An MCNP-based model of linear accelerator xray beam, Phys Med Biol. 44 (1999) 1219–1230.
[12] D.W.O. Rogers, B. Walters, I. Kawrakow, BEAMnrcUser's. NRC Report PIRS 509, Canada, (2013).
[13] B. Walters, I. Kawrakow, D.W.O. Rogers, DOSXYZnrc Users Manual. NRC Report PIRS 794, Canda, (2013).
[14] WORKING GROUP6: COMPUTATIONAL DOSIMETRY. Standard Monte Carlo Modeling of a Medical Linear Accelerator, (2010).
[15] Siemense medical solution USA INC oncology care systems group
[16] M. Mahdavi, M. Hoseinnezhad, S.R. Mahdavi. Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry. IJMP 15(4) (2018) 243–250.
[17] M. Chen, W. Lu, Q. Chen, K. Ruchala, G. Olivera. Efficient gamma index calculation using fast Euclidean distance transform. Med Phys. 54 (2009) 2037–2047.