[1] W. Stachowicz, G. Strzelczak-Burlinska, J. Michalik, A. Wojtowicz, A. Dziedzic-Goclawska, K. Ostrowski, Application of electron paramagnetic resonance (EPR) spectroscopy for control of irradiated food, Journal of the Science of Food and Agriculture, 58 (1992) 407-415.
[2] K. Mahesh, Techniques of Radiation Dosimeter, Wily Eastern Ltd, New Delhi, India, (1985).
[3] K.W. Bögl, D.F. Regulla, M.J. Suess, Health impact, identification, and dosimetry of irradiated food, Institut für Strahlenhygiene(1988).
[4] F. Ziaie, W. Stachowicz, G. Strzelczak, S. Al-Osaimi, Using bone powder for dosimetric system EPR response under the action of γ irradiation, Nukleonika, 44 (1999) 603-608.
[5] N. Hajiloo, F. Ziaie, M. Hesami, Use of hydroxyapatite prepared by sol-gel method for gamma ray and electron beam dosimetry, Journal of Nuclear Science and Technology, 2 (2011) 15-21.
[6] P. Moens, P. Devolder, R. Hoogewijs, F. Callens, R. Verbeeck, Maximum-likelihood common-factor analysis as a powerful tool in decomposing multicomponent EPR powder spectra, Journal of Magnetic Resonance, Series A, 101 (1993) 1-15.
[7] F. Ziaie, N. Hajiloo, R. Amraei, Comparison of Synthesized Micro-and Nanostructure Hydroxyapatite for EPR Dosimetry, BioNanoScience, 2 (2012) 104-107.
[8] N. Hajiloo, F. Ziaie, S. Mehtieva, Gamma-irradiated EPR response of nano-structure hydroxyapatite synthesised via hydrolysis method, Radiation protection dosimetry, 148 (2012) 487-491.
[9] F. Ziaie, N. Hajiloo, A. Alipour, R. Amraei, S. Mehtieva, Retrospective dosimetry using synthesized nano-structure hydroxyapatite, Radiation protection dosimetry, 145 (2011) 377-384.
[10] H. Lanjanian, F. Ziaie, M. Modarresi, M. Nikzad, A. Shahvar, S. Durrani. A technique to measure the absorbed dose in human tooth enamel using EPR method, Radiation Measurements, 43 (2008) S648-S650.
[11] J. Talpe, Theory of Experiments in Paramagnetic Resonance: International Series of Monographs in Natural Philosophy, Elsevier(2013).
[12] IAEA-TECDOC-1331, Use of Electron Paramagnetic Resonance Dosimetry with Tooth Enamel for Retrospective Dose Assesment, Vienna: International Atomic Energy Agency, Vienna, Austria, (2002).
[13] B. Culity, S. Stock, Elements of X-ray Diffraction, Reading: Addition-Wesley, (1978).
[14] Z. Zyman, M. Tkachenko, CO 2 gas-activated sintering of carbonated hydroxyapatites, Journal of the European Ceramic Society, 31 (2011) 241-248.
[15] M.T. Fulmer, I.C. Ison, C.R. Hankermayer, B.R. Constantz, J. Ross, Measurements of the solubilities and dissolution rates of several hydroxyapatites, Biomaterials, 23 (2002) 751-755.