In this study, due to the importance of calibration in accurate dose measurement, we performed this process accurately and displayed the method and results in various diagrams. Also, using thermoluminescence dosimeters, gamma and neutron beams were measured. According to these results, the amount of gamma ray is 21 and the amount of neutron is 3 µSv/h per hour for flying in foreign routes and also for domestic routes, the amount of gamma ray is 2 and the neutron value is 0.1 µSv/h. It should be noted that all flight paths were done randomly at different altitudes.
م. زاهدی فر، ا. صادقی. ترمولومینسانس نانوساختارها, چاپ اول. کاشان 1395.
ر. فقیهی، س. مهدی زاده، م. جعفری زاده، ص. سینا، م. زه تابان، م. طاهری. اندازهگیری دز پرتوهای کیهانی در ارتفاعهای مختلف جو ایران. مجله علوم و فنون هسته ای .33 (1) (1391) 32-26.
M. Sohrabi, A. R. Solaymanian. Some characteristics of the AEOI passive radon diffusion dosimeter. Int. J. Radiat. Appl. Instrumentation. Part D. Nucl. Tracks Radiat. Meas. 15 (1-4) (1988) 605-608.
M. Taheri, S. Hosseini Toudeshki. Characteristic studies for fast detection of a wide energy range of alpha particles in polycarbonate detectors. Radiat. Meas. 40 (2-6) (2005) 307-310.
M. Danilkin, A. Lust, M. Kerikmae, V. Seeman, H. Mandar, M. Must. CaF2: Mn extreme dosimeter: Effects of Mn concentration on thermoluminescence mechanisms and properties. Radiat. Meas. 41 (2006) 677-681.
Bozorgi, S., Monemzadeh, M., & Zahefi far, M. (2022). Calibration of thermoluminescence dosimeters and measurement of gamma and neutron beam doses in passenger flights by these dosimeters. Journal of Radiation Safety and Measurement, 11(3), 157-163. doi: 10.22052/rsm.2023.248281.1004