Dose of scattered neutrons in calibrated neutron field

Document Type : Conference Paper

Authors

Physics Department, Islamic Azad University Centeral Tehran Branch, Tehran, Iran

Abstract

Given that neutron is a non-load-bearing particle that quickly responds to environmental elements and leads to ionization of elements, as well as dispersion that affects neutron spectrum due to environmental factors. Dosage of dispersed neutrons, as well as minimizing dispersion factors is the goal of this research. Calibration can be defined as a set of operations under specified conditions that measure the relationship between the values measured by the measuring instrument or system and the Similarly known well known values of a value.

Keywords


  1. ک. کرین. آشنایی با فیزیک هسته‌ای. چاپ چهارم، جلد دوم، ترجمه‌: ن. میرفخرایی، م. مدرس. مرکز نشر دانشگاهی، تهران 1393.
  2. ک. اچ. بکرتس، ک. ویرتز. فیزیک نوترون. ترجمه‌:‌ ع.‌ افشاری‌کشلو، ع. ‌پذیرنده، انتشارات دانشگاه تهران، تهران، 1352.
  3. G. F. Knoll, Radiation Detection and Measurement, 4th ed, John Wiley & Sons, New York, 1999.
  4. آ. .فوستر، ر .رایت. مهندسی هسته‌ای پایه. ترجمه‌: ع. افشاری کشلو، م. رهبر. دانشگاه شیراز، مرکز نشر (مرکز نشر دانشگاه‌ شیراز)، 1364.
  5. ج. کنت شولتیس، ر. ای فاو. حفاظ‌سازی تابش. ترجمه: س. بیات، س. م. وهابی، ع. حسین‌زاده. سیمای دانش، آذر، 1396.
  6. BSI-British standard Institution, ISO 8529-1:2001(E).
  7. م. صالحی. مبانی و کاربرد دانش هسته‌ای. جهاد دانشگاهی (دانشگاه صنعتی امیرکبیر)، 1387.
  8. L. Dresner. Principles of Radiation Protection Engineering. Oak Ridge National Laboratory, 1965.
  9. M. Winter, P. Beck, P. Kindl, S. Kerschbaumer. Characterisation of radiation detectors in photon and high energetic particle fields. Proceedings of the IRPA regional symposium on radiation protection in neighbouring countries of Central Europe, (p. 671). Czech Republic, 1998.
  10. ن. سولفانیدیس، انـدازه‌گیری و آشکارسـازی تابش‌های هسته‌ای. ترجمه: ر. کوهی، م .ه. هادی‌زاده یزدی، انتشارات سیمین، 1390.
  11. ه. سمت، ج. ر. آلبرایت. آشنایی با فیزیک اتمی و هسته‌ای. جلد دوم، ترجمه‌ خسرو بخشایی، مرکز نشر دانشگاهی، 1401.
  12. Software Janis. ( Java Nuclear Information Software).
  13. N. Ghaleh, Modeling Photon Transport in Scintillators. PhD Thesis, School of Science Ferdowsi University of Mashhad, Mashhad, Iran, 2003.
  14. C. M. Eisenhauer, R. B. Schwartz, T. Johnson. Measurement of neutrons reflected from the surfaces of a calibration room. Health Phys. 42 (1982) 489-495.
  15. K. S. Lim, B. H. Kim, S. Y. Chang. Calibration of neutron measuring instruments by 252Cf neutron source. Transactions of the Korean Nuclear Society Autumn Meeting Busan, Korea, 2005.
  16. S. K. Lee, B. -H. Kang, G. -D. Kim, Y.-K. Kim. Fast neutron detector for fusion reactor KSTAR using stilbene scintillator. arXiv:1112.5963v1 [nucl-ex] (2011).
  17. ISO 10647. Procedures for calibrating and determining the response of neutron-measuring devices used for radiation protection purposes. International Organization for Standardization. Geneva, Switzerland, 1996.