Absorbed dose of Fetus in SPECT-CT Imaging of Mother's Abdomen Regions using Monte Carlo method

Authors

Abstract

SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period before birth, there may be harmful and irreversible effects on the fetus; therefore protecting the pregnant woman and the fetus against radiation is of great importance. The purpose of this study is to evaluate and calculate the fetus absorption dose in cardiac imaging using the SPECT-CT machine in stress and resting conditions of the cardiac by injecting 20 mCi of radiopharmaceutical of 99mTc-MIBI.  In order to evaluate the fetus absorption dose, the Monte Carlo method, using the MCNPX code and the ORNL phantom, was applied to simulate the fetus in three, six and nine months of pregnancy, and the radiation absorbed doses of fetus absorption were calculated in two condition of stress and rest.
The absorbed dose of fetus in stressed state in three, six and nine months of gestational age are 1.26 × 10-2, 2.9 × 10-3, 2.83 × 10-4  mGy respectively and The fetus absorption dose in rest in three, six and nine months of gestational age are  2.52 × 10-2, 5.79 × 10-3, 5.68 × 10-4 mGy respectively. The results of this study indicate that the highest fetus absorption dose is related to cardiac resting imaging at the third month of the fetus. The fetus absorption dose has been calculated to be less than 0.05 Gy for all maintenance periods, which, according to the NCRP 128 and ICRP 84, do not cause a serious risk to the fetus. However, special immunological advices should also be given to pregnant women to reduce the absorption of fetus, especially in the early months of pregnancy.
 
 

Keywords


[1] Solidrissa, A., Assessment of radiation dose to patients during single photon emission computed tomography (SPECT) 99mTc-sestamibi myocardial perfusion imaging (MPI) on Niamey-neger, Department of medical physics school of nuclear and allied sciences, university of Ghana, (2016). [2] http://www.Drugs.com/pro/technetium-tc-99m-sestamibi.html. [3] Xu, X. G., Eckerman, K.F., HANDBOOK of anatomical models for radiation dosimetry, Taylor and Froncis group. [5] Zanotti-fregonara, P., Laforest, R., Wallis, J.W., Fetal radiation dose from 18F-FDG in pregnant patients imaged with PET , PET/CT , PET/MR, The Journal Nuclear Medicine, vol. 56, (8) , (2015), pp. 1218-1222. [6] Zanotti-Fregonara, P., Jan, S., Taieb, D.E., et al, Absorbed 18F-FDG dose to the fetus during early pregnancy, The Journal Nuclear medicine, vol. 51, (5), (2010), pp. 803-805. [7] https://emergency.cdc.gov/radiation/prenatalphysician.asp.