Evaluation of gray scale changes of CBCT system images in different axis using the DICOM file

Authors

Abstract

The images of dental CBCT imaging systems used in conic shaped beams, stored in the DICOM format, have various applications in the dentistry, including bone density estimation to select the location of the orthodontic implant, bone loss detection and etc. In these systems, unlike CT imaging systems, the resulting images exhibit gray-scale non-uniformity in each of the different axis in FOV. This specification along with the inability of the CBCT to display the CT numbers accurately, makes it difficult to obtain bone density information, so diagnosing of dental complications using a quantitative information from the images cannot obtained accurately. In this regard, in order to be able to use the quantitative information of the images of these systems to assess more precisely the bone density, the gray scale changes in the images of several different CBCT systems were studied. The results showed that the process of gray scale changes for each system in each direction is unique for the each system, and it can be concluded that in each system, changes in the gray scale of images in each direction have a roughly constant trend. One of the most important results is that the gray scale changes of the images for all systems along the axis of the body (Z axis) have a steady trend and It has the lowest standard deviation. One of the most important results is that the gray scale changes of the images for the Scanora 3D and  New Tom GIANO systems in the axis of the body (Z axis) have a stable trend and the lowest standard deviation (0.54 ± 0.009) And (0.18 ± 0.004) respectively.
 

Keywords


[1] R. Kanagaratnam. Comparative study of orthopantomograph and cone beam computed tomography as pre-operative diagnostic tools for lower third molar surgery, Master's thesis, University of Sydney, (2014). [2] N. Emadi, Y. Safi, A.A. Bagheban and S. Asgary. Comparison of CT-number and gray scale value of different dental materials and hard tissues in CT and CBCT. Iranian endodontic journal, 9(4) (2014) 283–288. [3] J.C. Kwong, J.M. Palomo, M.A. Landers, A. Figueroa and M.G. Hans. Image quality produced by different cone-beam computed tomography settings. American Journal of Orthodontics and Dentofacial Orthopedics, 133(2) (2008) 317–327. [4] T. Razi, M. Niknami and F.A. Ghazani. Relationship between Hounsfield unit in CT scan and gray scale in CBCT. Journal of dental research, dental clinics, dental prospects, 8(2) (2014) 107–115. [5] D. Schulze, M. Heiland, H. Thurmann and G. Adam. Radiation exposure during midfacial imaging using 4-and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography. Dentomaxillofacial Radiology, 33(2) (2004) 83–86. [6] N. Kamaruddin, Z.A. Rajion, A. Yusof and M.E. Aziz. Relationship between Hounsfield unit in CT scan and gray scale in CBCT. In AIP Conference Proceedings, 1791(1) (2016). [7] R. Pauwels, O. Nackaerts, N. Bellaiche, H. Stamatakis, K. Tsiklakis, A. Walker H. Bosmans, R. Bogaerts, R. Jacobs, K. Horner and SEDENTEXCT Project Consortium. Variability of dental cone beam CT grey values for density estimations. The British journal of radiology, 86(1021) (2013) 20120135–20120141. [8] T.E. Reeves, P. Mah and W.D. McDavid. Deriving Hounsfield units using grey levels in cone beam CT: a clinical application. Dentomaxillofacial Radiology, 41(6) (2012) 500–508. [9] P. Mah, T.E. Reeves and W.D. McDavid. Deriving Hounsfield units using grey levels in cone beam computed tomography. Dentomaxillofacial Radiology, 39(6) (2010) 323–335. [10] C.A. Schneider, W.S. Rasband and K.W. Eliceiri. NIH Image to ImageJ: 25 years of image analysis. Nature methods, 9(7) (2012) 671–675.