Design and construction of an electric and magnetic field survey meter for assessing the health of workers of electric power substations

Author

10.22052/6.2.17

Abstract

In the extremely low frequency range (3 to 300 Hz), the intensities of electric and magnetic fields increase with increasing voltage and current. If the intensities of electric and magnetic fields are high compared with standard exposure limits, they can have harmful effects on human health. In the vicinity of power lines and high voltage power stations, the intensities of these fields are usually high. Therefore, in order to protect the workers and the general public against electric and magnetic fields, measurement of the intensities of the electric and magnetic fields with a suitable and calibrated device is necessary. Then the measurement results should be compared with the reference levels proposed in the national standard of Iran. In this paper, a constructed measuring device (as a survey meter) is discussed. Then the calibration system and its method are argued. Finally, the calibrated survey meter was used for measurement of electric and magnetic fields near to equipment installed in power stations. The measurement results are compared with the reference levels given in national standard. Accordingly, suggestions are made to optimize the conditions.
 
 

Keywords


[1] World Health Organization (WHO), E.L.F.F.E , Health Criteria Monograph, 238 (2010). [2] R.R. Neutra. Glossary of Terms Used When Discussing Exposure to Electric and Magnetic Fields, Journal of epidemiology and community health, 59(7) (2005) 546. [3] A. Zolfaghari and F. Kolahan. Reliability and Sensitivity of Magnetic Particle Nondestructive Testing in Detecting the Surface Cracks of Welded Components, Nondestructive Testing and Evaluation, (2018) 1–11. [4] K . Ilonen, A. Markkanen, G. Mezei and J. Juutilainen. Indoor Transformer Stations as Predictors of Residential Elf Magnetic Field Exposure, Bioelectromagnetics, 29(3) (2008) 213–218. [5] J.-E. Deadman, B.G. Armstrong and G. Thériault. Exposure to 60-Hz Magnetic and Electric Fields at a Canadian Electric Utility, Scandinavian journal of work, environment & health, (1996) 415–424. [6] T. Barsam, M.R. Monazzam, A.A. Haghdoost, M.R. Ghotbi and S.F. Dehghan. Effect of Extremely Low Frequency Electromagnetic Field Exposure on Sleep Quality in High Voltage Substations, Iranian journal of environmental health science & engineering, 9(1) (2012) 15. [7] V.R. Gandhewar, S.V. Bansod and A.B. Borade. Induction Furnace-a Review, International Journal of Engineering and Technology, 3(4) (2011) 277–284. [8] M. Misakian. Elf Electric and Magnetic Field Measurement Methods, International Symposium on Electromagnetic Compatibility, (1993). [9] Y. Hobara, H. Yamaguchi, Y. Akinaga, T. Watanabe, H. Koons, J. Rieder and M. Hayakawa. New Ulf/Elf Measurement in Seikoshi, Izu Peninsula, Japan, in, Abstracts and Program of International Workshop on Seismo Electromagnetics. The University of Electro-Communications, Chofu-city, Tokyo, September, (2000). [10] K. Shimizu, H. Endo and G. Matsumoto. Fundamental Study on Measurement of Elf Electric Field at Biological Body Surfaces, IEEE transactions on instrumentation and measurement, 38(3) (1989) 779–784. [11] N. Hayashi, K. Isaka and Y. Yokoi. Elf Electromagnetic Environment in Power Substations, Bioelectromagnetics, 10(1) (1989) 51–64. [12] International Agency For Research On Canceriarc (IARC), Non-Ionizing Radiation: Static and Extremely Low-Frequency (ELF) Electric and Magnetic Fields, (2002). [13] IEEE, Recommended Practice for Measurements and Computations of Electric, Magnetic, and Electromagnetic Fields with Respect to Human Exposure to Such Fields, 0hz to 100khz, (2010). [14] ICNIRP, Guidelines for Limiting Exposure to Time-Varying Electric and Magnetic Fields (1 Hz to 100 Khz), Health Physics, (2010). [15] ICNIRP, Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (up to 300 Ghz). International Commission on Non-Ionizing Radiation Protection (ICNIRP), Health Phys, (1998). [16] Institute of Standards and Industrial Research of Iran (ISIRI), Non-Ionizing Radiation Exposure Limits, (2016).