Study the attenuation ability of the composites containing micro and nano-sized tungsten oxide and lead oxide as diagnostic X-ray shields

Authors

10.22052/5.3.15

Abstract

The attenuation ability of composites containing micro and nano-sized WO3 was measured and compared with the attenuation ability of composites containing micro-size and nano-sized PbO for X-rays in diagnostic energy range. For the purpose, after synthesizing nano and micro-scaled particles, different percentages of them were imbedded in poly vinyl chloride (EPVC) emulsion and prepared as shields with the thickness of about 2mm and exposed to 40-100 kVp < /sub> range. Transmitted dose, density and mass attenuation coefficient of prepared samples were determined and compared with previous studies. According to the results, the attenuation ability of nano-particle containing shields is better than the ability of micro-particle contained ones. Also the results for WO3 containing samples differ slightly from the results of PbO contained ones. In addition, all of the prepared samples have very lower density than PbO and WO3. Thus, the shields containing nano WO3 are light, flexible and could be a suitable alternative for lead aprons.

Keywords


[1] S.H.L. JaeWoo Kim,Y. Rang Uhm, B. Lee, J. Jung, Ch. Kyu Rhee, M.K. Lee, H. Min Lee. Radiation shielding members including nano-particles as a radiation shielding material and method for preparing the same, US8318045 B2, )2009(. [2] H.A. Maghrabi, A. Vijayan, P. Deb, L. Wang. Bismuth oxide-coated fabrics for X-ray shielding, Text. Res. J. 86 (2016) 649–658. [3] Z. Kargar, N. Ghahramany. Radioisotopes and their applications in nuclear physics, Shiraz University Press, Shiraz,Iran, 2002. [4] D. Storm. Ten Principles and Ten Commandments of Radiation Protection. Health Physics, Health Phys. 70 (1996) 388–393. [5] J.P. McCaffrey, H. Shen, B. Downton, E. Mainegra-Hing. Radiation attenuation by lead and nonlead materials used in radiation shielding garments, Med. Phys. 34 (2007) 530–7. [6] Z.W. Li Liu, L. Zhang, H. Shui, W. Shipeng. Lead-free X-ray shielding rubber composite, US8728349 B2, (2009). [7] NCRP151, (2005). [8] S.C. Kim, K.R. Dong, W.K. Chung. Medical radiation shielding effect by composition of barium compounds, Ann. Nucl. Energy. 47 (2012) 1–5. [9] J.P. McCaffrey, H. Shen, B. Downton, E. Mainegra-Hing. Radiation attenuation by lead and nonlead materials used in radiation shielding garments, Med. Phys. 34 (2007) 530–537. [10] J. Kim, D. Seo, B.C. Lee, Y.S. Seo, W.H. Miller. Nano-W Dispersed Gamma Radiation Shielding Materials, Adv. Eng. Mater. 16 (2014) 1083–1089. [11] N.Z. Noor Azman, S.A. Siddiqui, I.M. Low. Characterisation of micro-sized and nano-sized tungsten oxide-epoxy composites for radiation shielding of diagnostic X-rays, Mater. Sci. Eng. C. 33 (2013) 4952–4957. [12] A. Aghaz, R. Faghihi, S.M.J. Mortazavi, A. Haghparast, S. Mehdizadeh, S. Sina. Radiation attenuation properties of shields containing micro and Nano WO3 in diagnostic X - ray energy range, Int. J. Radiat. Res. 14 (2016) 127–131. [13] M. Kajeh Aminian, J. Ye. Morphology influence on photocatalytic activity of tungsten oxide loaded by platinum nanoparticles, J. Mater. Res. 25 (2010) 141–148. [14] N. Mythili, K.T. Arulmozhi. Studies on the electrical and dielectric properties of chemically synthesized α-PbO nanoparticles, Appl. Phys. A. 118 (2015) 261–267. [15] H. Chai, X. Tang, M. Ni, F. Chen, Y. Zhang, D. Chen, Y. Qui. Preparation and properties of novel, flexible, lead-free X-ray-shielding materials containing tungsten and bismuth(III) oxide. J Appl Polym Sci. 133 (2016) 1–7