Dosimetry of a dual-energy cargo inspection system using monte carlo simulation

Authors

10.22052/3.3.1

Abstract

Todays, X-ray imaging system for cargo and containers inspecting of country gates are highly regarded. The dual energy imaging system due to the use of two beams with different spectrums can extracts more information about the materials in cargo than the conventional X-ray imaging system. Since the X-ray beam is an ionizing radiation, three parameters should be taken into account including justifiably, optimization and dose limits. In this study to evaluate the exposure for materials inside cargo, staffs and for around of system, we simulated a typical system using Monte Carlo code. With using 750 mCi of 137Cs and 1 Ci of 60Co, exposure rates for the water phantom in the center of cargo were 10μSv/h and 20μSv/h for 137Cs and 60Co, respectively. Also, the exposure rate at a distance of 10 meter around the system without any additional protection lies almost in the appropriate value. The results of simulations show that with using the line scan system and a good designing for source shielding, the exposure at cargo inside and environment of it can be put in suitable values.

Keywords


[1] B.G. Brown. X-rays and Their Applications. Springer Science & Business Media, (2012). [2] G.F. Knoll. Radiation detection and measurement. John Wiley & Sons, (2010). [3] ICRP. Recommendations of the International Commission on Radiological Protection. Publication 60, Annals of the ICRP,Pergamon Press, Oxford, 21 (1991)1–3. [4] IAEA. TECDOC-953. International Atomic Energy Agency, Vienna. IAEA (2006). [5] H. Cember. Introduction to health physics.McGrawHill, New York, (1969). [6] R.L. Brent. The effect of embryonic and fetal exposure to x-ray, microwaves, and ultrasound: counseling the pregnant and nonpregnant patient about these risks. Semin Oncol,16 (1989) 347-368. [7] J. Hendricks, G. McKinney, L. Waters, MCNPX User’s Manual, version 2.5. 0, Los Alamos National Laboratory, (2005). [8] J. Eberhardt, S. Rainey, R. Stevens, B. Sowerby, and J. Tickner. Fast neutron radiography scanner for the detection of contraband in air cargo containers. Applied Radiation and Isotopes, 63 (2005) 179-188. [9] J.T. Bushberg, and J. M. Boone. The essential physics of medical imaging. Lippincott Williams & Wilkins, (2011). [10] F. Hsu, W. Lee, C. Tung, J. Lee, T. Wu, S. Hsu, H. Su, and T. Chen. Ambient and personal dose assessment of a container inspection site using a mobile X-ray system. Applied Radiation and Isotopes, 70 (2012) 456-461. [11] J. Rodier, and J. Chassany. Manual de Radio Protection. Malonie. SA Editor, (2007). [12] B.R. Archer. History of the shielding of diagnostic x-ray facilities. Health physics, 69 (1995)750-758.