Simulation and performance evaluation of coded aperture gamma imager system with wide field of view

Document Type : Original Article

Authors

Faculty of Science, University of Imam Hossein, Babaei Hwy, Tehran, Iran

Abstract

Accurate detection and localization of radioactive materials is crucial in nuclear imaging, especially given the growing threat of attacks and proliferation of nuclear power plants. A dependable imaging system capable of detecting gamma rays at varying distances is essential for timely identification and localization of radiation sources. Coded aperture imaging (CAI) is a promising method due to its ability to capture more photons and produce higher quality images, albeit more complex. The resolution of decoded images can be improved with the maximum likelihood expectation maximization (MLEM) algorithm. In this study, the GATE code was used to simulate a gamma camera with mosaic MURA coded apertures, with a NaI(Tl) detector measuring 27 × 27 × 2 cm³, to image sources of cesium-137 and americium-241. An angular resolution of about 7 degrees was achieved at a distance of 3 meters. estimated minimum equivalent dose for imaging at a distance of 10 meters using the cesium-137 source was 0.179 nSv/hr (with an activity of 6 microcuries). The signal-to-noise ratio at this distance was equal to 3.10, but after applying the MLEM algorithm, it increased to 17.96. The importance of this research lies in its potential applications for nuclear disarmament, border monitoring, and decontamination, where the location of radioactive sources is often unknown.

Keywords


  1. M. G. Cieślak, A. A. Kelum, R. Glover. Coded-aperture imaging systems: Past, present and future Development - A review. Radiat. Measurements 92 (2016) 59-71.
  2. M. N. Wernick, J. N. Aarsvold. Emission Tomography: The Fundamentals of PET and SPECT. Elsevier academic press, Boston, 2004.
  3. J. Hong, S. V. Vadawale, M. Zhang, E. C. Bellm, A. Yousef, J. Noss, J. E. Grindlay, T. Narita. Laboratory coded aperture imaging experiments: radial hole coded masks and depth-sensitive CZT detectors. In: Res. Sect. A Proceedings SPIE, Hard Xray and Gamma-Ray Detector Physics VI 5540 (2004) pp. 1-10.
  4. N. Gehrels, G Chincarini, P. Giommi, K. O. Mason, J. A. Nousek, A. A. Wells, N. E. White, S. D. Barthelmy, D. N. Burrows, L. R. Cominsky, K. C. Hurley, F. E. Marshall, P. M´esz´aros, P. W. A. Roming, L. Angelini, L. M. Barbier, T. Belloni, P. T. Boyd, S. Campana,P. A. Caraveo, M. M. Chester,O. Citterio, T. L. Cline, M. S. Cropper, J. R. Cummings, A. J. Dean, E. D. Feigelson, E. E. Fenimore, D. A. Frail, A. S. Fruchter17, G. P. Garmire, K. Gendreau,G. Ghisellini, J. Greiner, J. E. Hill, S. D. Hunsberger, H. A. Krimm,S. R. Kulkarni, P. Kumar, F. Lebrun, N. M. Lloyd-Ronning, C. B. Markwardt,B. J. Mattson, R. F. Mushotzky, J. P. Norris, B. Paczynski, D. M. Palmer, H.-S. Park26, A. M. Parsons, J. Paul, M. J. Rees, C. S. Reynolds, J. E. Rhoads, T. P. Sasseen28, B. E. Schaefer, A. T. Short, A. P. Smale, I. A. Smith, L. Stella, M. Still, G. Tagliaferri, T. Takahashi, M. Tashiro, L. K. Townsley, J. Tueller, M. J. L. Turner, M. Vietri, W. Voges, M. J. Ward, R. Willingale, F. M. Zerbi, W. W. Zhang. The swift gamma ray burst mission. Astrophysical J. 611 (2) (2004) 1005-1020.
  5. T. Tumerl, T. J. O. Neilll, K. Hurley, H. Ogelman, R. J. Paulos, R. C. Puettefl, I. Qpniss, W. J. Hamilton, R. Proctor. All-sky x-ray & gamma-ray astronomy monitor (AXGAM). IEEE Trans. Nucl. Sci. 44 (3) (1997) 572-576.
  6. M. Alnafea, K. Wells, N. M. Spyrou, M. I. Saripan, M. Guy, P. Hinton. Preliminary results from a Monte Carlo study of breast tumour imaging with lowenergy high-resolution collimator and a modified uniformly-redundant arraycoded aperture. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Assoc. Equip. 563 (1) (2006) 146-149.
  7. A. L. Damato, B. K. P. Horn, R. C. Lanza.Coded source imaging for neutrons and X-rays. IEEE Nucl. Sci. Symposium Conf. Rec. 1 (2007) 199-203.
  8. A. A. Faust, R. E. Rothschild, P. Leblanc, J. E. McFee. Development of a coded aperture X-Ray backscatter imager for explosive device detection. IEEE Trans. Nucl. Sci. 56 (1) (2009) 299-307
  9. M. Gmar, M. Agelou, F. Carrel, V. Schoepff. GAMPIX: a new generation of gamma camera. Nucl. Instrum. Methods Phys. Res. 652 (1) (2011) 638-640.
  10. M. Woodring, D. Beddingfield, D. Souza, G. Entine, M. Squillante, J. Christian, A. Kogan. Advanced multi-dimensional imaging of gamma-ray radiation. Nucl. Instrum. Methods Phys. (2003) 415-419.
  11. R. S. Woolf, B. F. Phlips, A. L. Hutcheson, L. J. Mitchell, E. A. Wulf. An active interrogation detection system (ACTINIDES) based on a dual fast neutron/ gamma-ray coded aperture imager for Homeland Security (HST). 2012 IEEE Conference on Technologies in Malaysian, Waltham, MA, USA (2012) pp. 30-35.
  12. P. Hausladen, J. Newby, F. Liang, M. Blackston. The Deployable Fast-Neutron Coded-Aperture Imager: Demonstration of Locating One or More Sources in Three Dimensions. Oak Ridge National Laboratory is managed by UT-Battelle LLC for the US Department of Energy, 2013.
  13. Y. Sato, S. Ozawa. Remote radiation imaging system using a compact gamma-ray imager mounted on a multicopter drone. Nucl. Sci. Tech. (2017) 90-96.
  14. J. Kataoka, A. ishimoto. Handy Compton camera using 3D position-sensitive scintillators coupled with large-area monolithic MPPC arrays. Nucl. Instrum. Methods (2013) 403-407.
  15. S. Jan, G. Santin, D. Strul, S. Staelens, K. Assie, D. Autret, S. Avner, R. Barbier, M. Bardies, P. M. Bloomfield, D. Brasse, V. Breton, P. Bruyndonckx, I. Buvat, A. F. Chatziioannou, Y. Choi, Y. H. Chung, C. Comtat, D. Donnarieix, L. Ferrer, S. J. Glick, C. J. Groiselle, D. Guez, P.-F. Honore, S. KerhoasCavata, A. S. Kirov, V. Kohli, M. Koole, M. Krieguer, D. J. van der Laan, F. Lamare, G. Largeron, C. Lartizien, D. Lazaro, M. C. Maas, L. Maigne, F. Mayet, F. Melot, C. Merheb, E. Pennacchio, J. Perez, U. Pietrzyk, F. R. Rannou, M. Rey, D. R. Schaart, C. R. Schmidtlein, L. Simon, T. Y. Song, J.-M. Vieira, D. Visvikis, R. Van de Walle, E. Wieers, C. Morel. GATE: a simulation toolkit for PET and SPECT. Phys. Med. Biol. 49 (2004) 4543-4561.
  16. G. Knoll. Radiation Detection and Measurement. 3rd ed., john Wiley, New York, 2000.
  17. H. S. Lee, J. H. Kim, J. Lee, C. H. Kim. Development and performance evaluation of large-area hybrid gamma imager (LAHGI). Nucl. Eng. Tech. 53 (8) (2021) 2640-2645.
  18. J. Montemont, O. Monnet, L. Maingault, S. Stanchina, L. Verger, F. Carrel, H. Lemaire, V. Schoepff, G. Ferrand, A. -S. Lalleman, M. Phelps. Development and evaluation of a portable CZT coded aperture gamma-camera. ANIMMA Conf. Lisbon (Portugal), 2015.
  19. E. Massoud. Dose Assessment for some industrial gamma sources with an application to a radiation accident. Open J. Model. Simulat. 2 (1) (2014) 4-11.