Department of Physics, Faculty of Sciences, University of Guilan, Rasht, Iran
Abstract
Dose evaluation is one of the main steps in cancer treatment. In process of treatment it is always a concern to conentrate the absorbed dose on the effected area and reduce the abosorbed dose on healthy organs. Brachytherapy is One of the major cancer treatment methods which uses various radionucleids as source. Although the most common source in this method is Ir-192 but Cs-137 has also an extensive use too. In this study the Absorbed dose in the superficial brachytherapy for treatment of keloids has been evaluated. Cs-137 was chosen as source and MCNP4C code was employed for the simulation.
E. B. Podgorsak, Radiation Oncology Physics: A Handbook for Teachers and Students. International Atomic Energy Agency, 2005.
M. Ohta, N. Nakao, S. Kuribayashi, T. Miyashita, N. Shigematsu, N. Hayashizaki. Evaluation of radiation exposure in Ir-192 brachytherapy for treatment of keloids. Energy Procedia 131 (2017) 363-370.
K. A. Van Riper. Building geometry models for Monte Carlo transport codes," 2007 IEEE Nucl. Sci. Symposium Conf. Record, Honolulu, HI, USA (2007) 2008-2015.
ICRP, 2000 Annual Report International Commission on Radiological Protection (2002) 1-30.
M. Sullivan, Brachytherapy Discussion, 2016.
D. Delacroix, J. P. Guerre, P. Leblanc, C. Hickman. Radionuclide and radiation protection data handbook 2002. Rad. Prot. Dosim.98 (1) (2002) 5-6.
R. L. Bunting. Nuclear Data Sheets for A=137. Nucl. Data Sheets 15 (1975) 335-369.
G. Audi, F. G. Kondev, W. Meng, W. J. Huang, S. Naimi. The NUBASE2016 evaluation of nuclear properties, Chinese Phys. C 41 (3) (2017) 030001.
Sadremomtaz, A., & Kazemian, M. R. (2023). Absorbed dose evaluation in Superficial Brachytherapy for treatment of keloids using monte carlo code MCNP4C. Journal of Radiation Safety and Measurement, 11(5), 79-82.
MLA
Alireza Sadremomtaz; Mohammad reza Kazemian. "Absorbed dose evaluation in Superficial Brachytherapy for treatment of keloids using monte carlo code MCNP4C", Journal of Radiation Safety and Measurement, 11, 5, 2023, 79-82.
HARVARD
Sadremomtaz, A., Kazemian, M. R. (2023). 'Absorbed dose evaluation in Superficial Brachytherapy for treatment of keloids using monte carlo code MCNP4C', Journal of Radiation Safety and Measurement, 11(5), pp. 79-82.
VANCOUVER
Sadremomtaz, A., Kazemian, M. R. Absorbed dose evaluation in Superficial Brachytherapy for treatment of keloids using monte carlo code MCNP4C. Journal of Radiation Safety and Measurement, 2023; 11(5): 79-82.