In this study, calculations related to the mass attenuation coefficient (µ/ρ) of Polyethylene/Bismuth Oxide composite (HDPE-Bi2O3) for different weight percentages of Bi2O3 in the polymer matrix, namely 0 wt%, 1 wt%, 2 wt%, 3 wt%, 5 wt% and 8 wt% for photons with 59 keV energy that can be used in dental radiography centers were simulated using the MCNP code and results were compared with XCOM data. The simulation results of the mass attenuation coefficient of the composite in different weight fractions via the methods of MCNP and XCOM at 59 keV showed a good agreement with each other. The results of this study showed that the Polyethylene/Bismuth Oxide composite material in optimal weight fraction and thickness can be used as a radiation shield in dental radiography centers.

Keywords


  1. J. K. Shultis, R. E. Faw. Radiation Shielding. Prentice-Hall, Upper Saddle River, NJ, 1996.
  2. R. Mehrara, S. Malekie, S.M. Saleh Kotahi, S. Kashian. Introducing a novel low energy gamma ray shield utilizing polycarbonate bismuth oxide composite. Sci. Rep. 11 (2021) 10614.
  3. F. Kazemi, S. Malekie, M.A. Hosseini. A Monte Carlo study on the shielding properties of a novel polyvinyl alcohol (PVA)/WO3 composite, against gamma rays, using the MCNPX code. J. Biomed. Phys. Eng. 9 (2019) 465.
  4. S. Malekie, N. Hajiloo. Comparative study of micro and nano size WO3/E44 epoxy composite as gamma radiation shielding using MCNP and experiment. Chin. Phys. Lett. 34 (2017) 108102.
  5. I. -M. Low, N. Z. N. Azman, Polymer Composites and Nanocomposites for X-Rays Shielding. Springer Singapore, 2020.
  6. S. Nambiar, E. K. Osei, J. T. Yeow. Polymer nanocomposite‐based shielding against diagnostic X-rays. J. Appl. Polym. Sci. 127 (2013) 4939-4946.
  7. M. I. Sayyed. Investigation of shielding parameters for smart polymers. Chin. J. Phys. 54 (2016) 408-415.
  8. H. O. Tekin, V. P. Singh, U. Kara, T. Manıcı, E. E. Altunsoy. Investigation of nanoparticle effect on radiation shielding property using Monte Carlo method. CBU J. Sci. 12 (2016) 195-199.