<ArticleTitle>Evaluating the observance of safety principles in imaging tests with common ultrasound waves in Ahvaz imaging centers</ArticleTitle>
<VernacularTitle>ارزیابی میزان رعایت اصول ایمنی در آزمون های تصویربرداری با امواج اولتراسوند متداول در مراکز تصویربرداری اهواز</VernacularTitle>
			<FirstPage>189</FirstPage>
			<LastPage>200</LastPage>
			<ELocationID EIdType="pii">112457</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>جعفر</FirstName>
					<LastName>فتاحی اصل</LastName>
<Affiliation>دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، خوزستان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>زهرا</FirstName>
					<LastName>فرزانگان</LastName>
<Affiliation>گروه تکنولوژی پرتودرمانی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی اراک، اراک، مرکزی، ایران</Affiliation>

</Author>
<Author>
					<FirstName>مرضیه</FirstName>
					<LastName>طهماسبی</LastName>
<Affiliation>دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، خوزستان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>شاداب</FirstName>
					<LastName>مرادی بیرگانی</LastName>
<Affiliation>دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، خوزستان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>مهرناز</FirstName>
					<LastName>ملک زاده</LastName>
<Affiliation>دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، خوزستان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>حمید</FirstName>
					<LastName>یزدانی نژاد</LastName>
<Affiliation>دانشگاه علوم پزشکی جندی شاپور اهواز، اهواز، خوزستان، ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2022</Year>
					<Month>08</Month>
					<Day>21</Day>
				</PubDate>
			</History>
		<Abstract>Despite the fact that the harmful effects of ultrasound waves have not been reported in previous studies, these rays are in the group of non-ionizing rays so as a form of energy have the potential to create biological effects when interacting with tissue. Accordingly, guidelines and recommendations have been proposed regarding the adjustment of scan parameters in ultrasound tests, especially pregnancy ultrasound to maintain the safety of patients and the fetus. Therefore, the aim of this study was to evaluate the scanning parameters and safety of common ultrasound tests used in diagnostic ultrasound centers. This descriptive cross-sectional study was performed by completing 321 checklists designed by researchers in Ahvaz ultrasound centers. Ultrasound examinations including routine pregnancy check-ups, examination of fetal abnormalities and pregnancy problems, initial diagnosis of the disease, and re-examination of cancer recurrence and metastasis were performed. In the examined tests, the standardization of specific parameters of the ultrasound system such as thermal indices (TI), mechanical (MI) and scan time were evaluated. In general, the maximum allowable values ​​of mechanical and thermal indicators for pregnancy tests are 1.0-0 and 0.4-0, respectively, and for non-pregnancy tests are 2.0-0 and 0.9-0, respectively. In this study, the mean thermal and mechanical indices for non-pregnancy tests were 0.30 ± 0.29 and 0.35 ± 1.07, respectively, and for pregnancy tests were 0.32 ± 0.27 and 0.13 ± 1.15, respectively. Based on this, for non-pregnancy tests, the mean of thermal and mechanical indices and scan time were within the standard and below the recommended values. For pregnancy tests, the mean heat index and scan time were appropriate, while the mean mechanical index was higher than the allowable limit for the first trimester of pregnancy. The results of this study indicated that the scan parameters used in the ultrasound examinations of Ahvaz imaging centers were appropriate and the examined examinations were relatively safe. However, more attention must be paid regarding the suitability of all scan parameters for pregnancy tests.</Abstract>
			<OtherAbstract Language="FA">با وجود عدم گزارش اثرات زیانبار امواج اولتراسوند در مطالعات گذشته و قرارگیری این پرتوها در گروه پرتوهای غیر یون‌ساز، این پرتوها به عنوان شکلی از انرژی،  توانایی بالقوه برای ایجاد اثرات زیستی هنگام بر هم کنش با بافت دارند. بنابراین، دستورالعمل ها و توصیه هایی در رابطه با تنظیم پارامترهای اسکن در آزمون های سونوگرافی، به ویژه سونوگرافی بارداری برای حفظ ایمنی بیماران و جنین، مطرح شده است. لذا، مطالعه حاضر با هدف ارزیابی پارامترهای اسکن و ایمنی آزمون های سونوگرافی متداول مورد استفاده در مراکز سونوگرافی تشخیصی، انجام شد. این مطالعه توصیفی - مقطعی، با تکمیل 321 چک لیست طراحی شده توسط محققان، در مراکز سونوگرافی اهواز انجام شد. آزمون های سونوگرافی شامل چک آپ های روتین بارداری، بررسی ناهنجاری های جنینی و مشکلات بارداری، تشخیص اولیه بیماری و بررسی عود مجدد و متاستاز سرطان مورد بررسی قرار گرفتند. در آزمون های مورد بررسی، استاندارد بودن پارامترهای اختصاصی سیستم اولتراسوند مانند شاخص های گرمایی(TI)، مکانیکی(MI) و زمان اسکن مورد ارزیابی قرار گرفتند. به طور کلی ماکزیمم مقدار مجاز شاخص های مکانیکی و گرمایی برای آزمون های بارداری به ترتیب 1.0-0 و 0.4-0 و برای آزمون های غیر بارداری به ترتیب 2.0-0 و 1.9-0 می باشد.  در این مطالعه میانگین شاخص های گرمایی و مکانیکی برای آزمون های غیر بارداری مورد بررسی، به ترتیب 0.30±0.29 و 0.35±1.07 و برای آزمون های بارداری به ترتیب 0.32±0.27 و 0.13±1.15 بود. بر اسن اساس برای آزمون های غیر بارداری، میانگین شاخص های گرمایی، مکانیکی و زمان اسکن در حد استاندارد و پایین تر از مقادیر توصیه شده بود. برای آزمون های بارداری نیز، میانگین شاخص گرمایی و زمان اسکن، مناسب بوده است در حالی که میانگین شاخص مکانیکی، بالاتر از حد مجاز برای سه ماهه اول بارداری بود. نتایج حاصل از این مطالعه نشان داد که پارامترهای اسکن مورد استفاده در آزمون های سونوگرافی مراکز تصویربرداری اهواز مناسب و آزمون های بررسی شده نسبتاً ایمن بوده اند. با این وجود در رابطه با مناسب بودن همه پارامترهای اسکن برای آزمون‌های بارداری باید دقت بیشتری صورت گیرد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">سونوگرافی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">شاخص مکانیکی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">شاخص گرمایی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مدت زمان اسکن</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ایمنی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://rsm.kashanu.ac.ir/article_112457_93ee4451a41238a4645f3dec66d3356d.pdf</ArchiveCopySource>
</Article>
</ArticleSet>