Volume 7, Issue 4 (12-2019)                   IJRSM 2019, 7(4): 53-58 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shabanpoor H, Rezaeian P, Alipoor A, sabouri dodran A A. Measurement of dose equivalent of hand and eye of a nuclear medicine center technician during preparation of radiopharmaceutical containing 99mTc. IJRSM. 2019; 7 (4) :53-58
URL: http://rsm.kashanu.ac.ir/article-1-503-en.html
Abstract:   (234 Views)
Due to gamma irradiation by radioisotopes use for therapy and diagnostics proposes such as 99mTc, workers of nuclear medicine centers receives dose. Value of the dose equivalent of workers is determined using personnel dosimeters. Preparation, administration and injection of radiopharmaceutical are perfumed by technician so, the hand of technician received dose. In this paper the value of dose equivalent of a technician working in nuclear medicine center was measured during preparation of radiopharmaceutical containing 99mTc using GR-200 dosimeters. The results show that maximum dose equivalent in fingers of a hand and eye is about 16 μSv and 3 μSv, respectively. Considering the annually time of work, dose equivalent of hand and eye is less than dose limit for these organs.
 
Full-Text [PDF 640 kb]   (53 Downloads)    
Type of Study: Applicable | Subject: Special

Send email to the article author


© 2020 All Rights Reserved | Iranian Journal of Radiation Safety and Measurement