zamani M, Rahimian Mohammadi E. Statistical comparison of microwave radiation leakage around the microwave ovens imported in Iran between 2005 and 2009. IJRSM. 2013; 1 (2) :1-4
URL: http://rsm.kashanu.ac.ir/article-1-26-en.html

researcher سازمان انرژی اتمی ایران
Abstract:   (6014 Views)

According to radiation protection regulations, microwave radiation intensity should not exceed general public exposure limit defined in "Iranian Standard-Non ionizing radiation-exposure limits". Based on this standard, exposure limit for microwave ovens, which work at 2450 MHz, is 1mW/cm2. By implementing such standard, about 575 imported ovens, including different models and brands were tested and categorized to four groups A, B, C, D based on the maximum microwave radiation around the oven. Microwave leakage for A, B, C groups were measured to be less than or equal to 0.1, 0.3, 0.5mW/cm2respectively but for group D was more than 0.5mW/cm2 .Result are presented and compared.

Full-Text [PDF 363 kb]   (1950 Downloads)    
Type of Study: Research | Subject: Special

Add your comments about this article : Your username or email:
Write the security code in the box

Send email to the article author


© 2015 All Rights Reserved | Iranian Journal of Radiation Safety and Measurement